SCOTS TRUGRIP™
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Metal roof and wall panel to wood structure. | |
| Metal panel over insulation to wood structure. | |
| Stitch metal roof and wall panel. |
| Integral washer head design seals even when driven at an angle. | |
| 300 series stainless head most preferred for galvalume long life panels. | |
| #10 Hi-Lo thread has 30% greater pullout than #9 in wood. | |
| Climaseal® long life finish resists corrosive elements in wood. | |
| A.P.T. point for fast cutting, easier tapping, and pigtail reducing. | |
| High-hat HWH for driving stability. |

![]()
Material............Case hardened carbon steel
Diameter...........#10 and #12
Thread Form.....10-16 Hi-Lo and 12-14
Head Style........1/4" Across Flats HWH
(300 Series Stainless)
Washer Style....7/16" O.D. Integral Head with EPDM Washer
Drill Point..........#10: A.P.T. (Anti-Pigtail Technology)
#12: Sharp
Finish...............Climaseal
Available with P3 powder paint
SCOTS Trugrip #9 only - (204 Kb.zip) |
In order to view ACAD 2004 files, the user must have either ACAD 2004, ACAD LITE 2004, or VOLO VIEW. These are the only programs we support.
![]()
![]()
Selector Guide
| Part Number | Description | Head Style | Drill Point | Drill & Tap Capacity | Material Attachment | Box Qty |
| 1951053 | 10-16 x 1" | HWH | A.P.T. | .012-.048 | 0-.250 | 2,500 |
| 1953053 | 10-16 x 1-1/2" | HWH | A.P.T. | .012-.048 | 0-.750 | 2,500 |
| 1955053 | 10-16 x 2" | HWH | A.P.T. | .012-.048 | .500-1.250 | 1,000 |
| 1957053 | 10-16 x 2-1/2" | HWH | A.P.T. | .012-.048 | 1.000-1.750 | 1,000 |
| 1691053 | 12-14 x 3/4" | HWH | Sharp | .012-.048 | - | 4,000 |
![]()
| PULLOUT VALUES IN STEEL (average lbs. ultimate) | |||||
| Fastener | Steel Gauge | ||||
| Dia. | 26 | 24 | 22 | 20 | 18 |
| 9 | 171 | 252 | 329 | 401 | 634 |
| 10 | 151 | 238 | 291 | 359 | 478 |
| 12 | 199 | 271 | 360 | 426 | 656 |
| PULLOUT VALUES IN WOOD (average lbs. ultimate) | |||||
| Fastener | Embedment in 2" x 4" (SYP) | ||||
| Dia. | 1/2" | 3/4' | 1 | 1-1/4" | 1-1/2" |
| 9 | 198 | 328 | 571 | 728 | 872 |
| 10 | 256 | 710 | 753 | 1121 | 1358 |
| 12 | 210 | 335 | - | - | - |
| Pullout Resistance from Lumber, OSB sheathing and CDX plywood | ||||||
| #9 | S-P-F #2 | Douglas Fir | OSB 5/8 | CDX 1/2 | CDX 5/8 | CDX 3/4 |
| Pullout in lbs. | 667 | 780 | 217 | 354 | 470 | 538 |
| PULLOVER VALUES (average lbs. ultimate) | ||||||
| Fastener | Steel Gauge | |||||
| Dia. | 26 | 24 | 22 | 20 | 18 | |
| 9 | Washered | 515 | 674 | 875 | 1100 | 1627 |
| 10 | Washered | 548 | 932 | 1122 | 1444 | 1894 |
| 12 | Washered | 587 | 744 | 915 | 993 | 1246 |
| FASTENER VALUES | |||
| Fastener (dia-tpi) | Tensile (lbs. min.) | Shear (avg. lbs. ult.) | Torque (min. in. lbs.) |
| 9-15 | 1800 | 1200 | 50 |
| 10-16 | 1927 | 1200 | 71 |
| 12-14 | 2778 | 2000 | 92 |
| SHEET STEEL GAUGES | |||||||
| Gauge No. | 18 | 20 | 22 | 24 | 26 | 28 | 30 |
| Decimal Equivalent | .048" | .036" | .030" | .024" | .018" | .015" | .012" |
The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes.
![]()
A standard screw gun with a depth sensitive nosepiece should be used in install Scots TruGrip. For optimal fastener performance, the screw gun should be a minimum of 4 amps and have a RPM range of 0-2000. | |
Adjust the screw gun nosepiece to properly seat the fastener. | |
New magnetic sockets must be correctly set before use. Remove chip build-up as needed. | |
Overdriving may result in torsional failure of the fastener or strip-out of the substrate. | |
The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. |
![]()
| Name | |
| Title | |
| Company | |
| Address | |
| E-mail required | |
| Phone required | use xxx-xxx-xxxx format |
| FAXNumber |
![]()
Last modified: July 28, 2010
Return to Home Page USA only - Information: submit a request or contact us. INTERNATIONAL - Information
ITW Buildex uses WebTrends to analyze traffic to this web site. WebTrends does not create individual profiles for visitors. Unlike some tracking services WebTrends does not have a database of individual profiles for each visitor. WebTrends only collects aggregate data. For more information about WebTrends privacy policy, please click here. Send mail to: webmaster@itwbuildex.com with questions or comments about the webpage. |