ROCK-ON™
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Cement-type boards or any dense sheathings to steel or wood studs. | |
| Wire lath to steel or wood studs. | |
| Plywood to steel or wood studs. | |
| Hardie Fiber Cement Backerboard |
![]()

Rock-On
| Rib design under head countersinks into dense material while preventing stripouts. | |
| Two point types for steel and wood applications. | |
| Larger head diameter increases board surface contact for greater pullover resistance. | |
| Rock-On is recommended for ACQ treated wood. Click on this link for further information about Buildex fasteners used in ACQ treated wood applications - ACQ Treated Wood Applications (.pdf 26 Kb) |

Backer-On
| Gimlet point starts easily - no predrilling. | |
| Serrated thread design provides reduced installation torque and superior holding power. | |
| Rib design under head countersinks into dense material while preventing stripouts. | |
| #2 square drive prevents bit from slipping. |

![]()
Rock-On
Diameter........#8; #9 Thread Form.....8-18; 9-15 HiLo® Drill Point.....#8 Type S-12®: #9 Type "S" Head Style......Wafer Head with countersinking ribs Finish..........Climacoat®
Backer-On
Diameter........#10 Thread Form.....10-10 Serrated Drill Point.....Gimlet Head Style......Wafer Head with countersinking ribs Finish..........Long life epoxy topcoat/zinc plating.
![]()
Rock-On; Climacoat Finish
Kesternich Results (DIN 50018, 2.0L)
| |||
Salt Spray Results (ASTM B117)
|
Backer-On; Epoxy topcoat/zinc plating
Kesternich Results (DIN 50018, 2.0L)
| |||
Salt Spray Results (ASTM B117)
|
![]()
Selector Guide
| Part# | Length | Material Attachment Range | Applications |
|
Hi-Lo® Rock-On | |||
| 2151500* | 9 x 1-1/4" | Up to 3/4" Material Thickness to Wood 3/8" - 1" Material Thickness to Steel | Cement Board to Wood or Light Gauge Steel 26-20 Gauge |
| 2153500* | 9 x 1-5/8" | Up to 1-1/8" Material Thickness to Wood 3/8" to 1-3/8" Material Thickness to Steel | |
| 2155500 | 9 x 2-1/4" | Up to 1-3/4" Material Thickness to Wood 1" to 1-7/8" Material Thickness to Steel | |
|
S-12™ Rock-On | |||
| 2156500* | 8 x 1-1/4" | 3/8" to 3/4" Material Thickness | Cement Board to Steel Studs 20-12 Gauge |
| 2159500* | 8 x 1-5/8" | 3/8" to 1-1/4" Material Thickness | |
| 2139500 | 8 x 2-1/4" | 1" to 1-7/8" Material Thickness | |
|
Backer-On™ | |||
| 2406000 | 10 x 1-1/4" | Up to 3/4" Material Thickness to Wood 3/8" - 1" Material Thickness to Steel | Backer Board |
* Fully Threaded
![]()
Performance Data
| Pullout Values in Steel (Gauge) | ||||||||
| 26 | 24 | 22 | 20 | 18 | 16 | 14 | 12 | |
| S-12® | 120 | 191 | 239 | 285 | 470 | 663 | 910 | 1424 |
| Hi-Lo® | 163 | 242 | 314 | 370 | - | - | - | - |
| Backer-On™ | 271 | 371 | 457 | 615 | ||||
|
Wood (Embedment) #2 SPF 2 X 4 | ||||
| 1/2" | 3/4" | 1" | 1-1/4" | |
| Hi-Lo® | 223 | 312 | 555 | 676 |
| Backer-On™ | - | 436 | 780 | - |
| Sheet Steel Gauges | ||||||||
| Gauge No. | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 |
| Decimal Equivalent | .105" | .075" | .060" | .048" | .036" | .030" | .024" | .018" |
The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes.
![]()
A standard screwgun with a depth sensitive nosepiece should be used in install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have a RPM range of 0-2500. | |
Adjust the screwgun nosepiece to properly seat the fastener. | |
Worn or damaged bit tips should be replaced. | |
The fastener is fully seated when the head is flush with the work surface. | |
Overdriving may result in torsional failure of the fastener or stripout of the substrate. | |
The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. |
![]()
| Name | |
| Title | |
| Company | |
| Address | |
| E-mail required | |
| Phone required | use xxx-xxx-xxxx format |
| FAXNumber |
Last modified: June 24, 2008
Return to Home Page USA only - Information: submit a request or contact us. INTERNATIONAL - Information
ITW Buildex uses WebTrends to analyze traffic to this web site. WebTrends does not create individual profiles for visitors. Unlike some tracking services WebTrends does not have a database of individual profiles for each visitor. WebTrends only collects aggregate data. For more information about WebTrends privacy policy, please click here. Send mail to: webmaster@itwbuildex.com with questions or comments about the webpage. |