GRID-MATE™ PB
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Attaching expanded polystyrene insulation to all substrates for all Polymer Based (PB) Exterior Insulated Finish Systems (EIFS) | |
| Attaching dense blanket or rigid insulation for parking garages, fireproofing, foundation walls and soundproofing. |
![]()
| Closure fingers keep coating out of contact with fastener head - no sink marks or bleed throughs. | |
| Large 2" diameter resists and distributes wind loads for a secure system. | |
| Climacoat® and Climaseal® fasteners. |
![]()
Diameter........2" Round
Material........White polypropylene
Part Number.....2189900

![]()
Kesternich Results (DIN 50018, 2.0L)
| 20 Cycles - 10% or less red rust |
Salt Spray Results (ASTM B117)
| 500 hours - 10% or less red rust |
Kesternich Results (DIN 50018, 2.0L)
| 30 Cycles - 10% or less red rust |
Salt Spray Results (ASTM B117)
| 720 hours - 10% or less red rust |
![]()
| Part Number | Description | Carton Qty | Carton Weight | Application |
| PB Washer | ||||
| 2189900 | Grid-Mate PB Washer | 1000 | 11 lbs. | - |
| Wood/Light Metal - #2 Phillips Bugle Head, Climacoat®, Hi-Lo® Thread Form | ||||
| 2311500 | 7 x 1-5/8" | 5000 | 23 lbs. | For use with plywood, OSB dimensional lumber and light gauge metal (26 gauge - 20 gauge). |
| 2312500 | 8 x 2" | 3500 | 28 | |
| 2313500 | 8 x 2-1/2" | 2500 | 21 | |
| 2314500 | 8 x 3" | 2000 | 20 | |
| 2315500 | 8 x 4" | 1000 | 13 | |
| 2316500 | 10 x 5" | 500 | 12 | |
| 2317500 | 10 x 6" | 1000 | 27 | |
| Steel Framing - #2 Phillips Bugle Head, Climacoat® Finish, S-12® Drill Point | ||||
| 2321500 | 6 x 1-5/8" | 5000 | 25 lbs. | For use with steel framing from 20 gauge - 12 gauge |
| 2318500 | 6 x 2" | 3500 | 28 | |
| 2319500 | 8 x 2-5/8" | 2500 | 26 | |
| 2320500 | 8 x 3" | 2000 | 24 | |
| 2322500 | 10 x 4" | 1000 | 21 | |
| 2323500 | 10 x 5" | 500 | 13 | |
| Masonry | ||||
| 3171407* | 3/16" x 1-3/4" | 100/500 | 5 lbs. | For use with brick, block and concrete |
| 3173407* | 3/16 x 2-1/4" | 100/500 | 6 | |
| 3175407* | 3/16 x 2-3/4" | 100/500 | 8 | |
| 3177407* | 3/16 x 3-1/4" | 100/500 | 9 | |
| 3181407* | 3/16 x 4" | 100/500 | 10 | |
| *5 Carbide Bits Per 500 Piece Master Carton | ||||
![]()
Performance Data
Pullout Values (Average lbs. ultimate)
Steel Applications
| Sheet Steel Gauges | ||||||||
| Fastener | 26 | 24 | 22 | 20 | 18 | 16 | 14 | 12 |
| Wood/Light Metal (Hi-Lo) | 129 | 178 | 244 | 277 | - | - | - | - |
| Steel (S-12) | - | - | - | 296 | 471 | 679 | 847 | 1,225 |
The values listed are ultimate average achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. Wind-load test results also available upon request.
Concrete/Masonry Applications
| Tapcon Diameter | 3000 PSI Concrete Embedment | Hollow Block Embedment | ||||||
| 1" | 1-1/4" | 1-1/2" | 1-3/4" | 1" | 1-1/4" | 1-1/2" | 1-3/4" | |
| 3/16" | 341 | 581 | 863 | 1059 | 209 | 357 | 468 | 547 |
Wood Applications
| Fastener | Plywood | OSB | Lumber (Embedment) | |||||
| 1/2" | 5/8" | 3/4" | 1/2" | 1/2" | 3/4" | 1" | 1-1/4" | |
| Wood/Light Metal (Hi-Lo) | 298 | 432 | 633 | 208 | 183 | 304 | 441 | 652 |
The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes.
![]()
Tools and Techniques
Use a 0-2500 RPM, 6 amp min. rated screwgun or cordless drill to install fasteners to wood and steel substrates. Use a hammer drill or rotary hammer to install Tapcon masonry anchors. | |
Seat Grid-Mate PB washers flush with or maximum 1/16" below insulation surface. Overdriving Grid-Mates may damage the washer and insulation. | |
Fasteners must penetrate steel substrates a minimum of 3 pitches of threads. | |
Replace worn or damaged bit tips to prevent damage to fastener head and its finish. | |
Consult EIFS system manufacturers specifications for appropriate fasteners spacing. |
![]()
| Name | |
| Title | |
| Company | |
| Address | |
| E-mail required | - |
| Phone required | use xxx-xxx-xxxx format |
| FAXNumber |
Last modified: June 24, 2008
Return to Home Page USA only - Information: submit a request or contact us. INTERNATIONAL - Information
ITW Buildex uses WebTrends to analyze traffic to this web site. WebTrends does not create individual profiles for visitors. Unlike some tracking services WebTrends does not have a database of individual profiles for each visitor. WebTrends only collects aggregate data. For more information about WebTrends privacy policy, please click here. Send mail to: webmaster@itwbuildex.com with questions or comments about the webpage. |