DEK-CAP™
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Metal Curbs | |
| Skylights | |
| Ridge Applications | |
| Jobsite Retrofit |
![]()
| Universal design allows use on left and right handed seams. | |
| Flexible, corrosion resistant aluminum base conforms to the majority of standing seam roof panels. | |
| Pre-formed panel profile shape is designed to reduce installation time. | |
| Fastening locations are clearly indicated for accurate installation. | |
| Dual underside ridges provide maximum sealing protection. | |
| Thermal elastomer material provides excellent resistance to ozone, ultra-violet light and extreme temperatures. | |
| Thermal elastomer has a continuous temperature of -40°F to +250°F. | |
| Expansion notch provides added installation flexibility. | |
| Interior panel stop ensures correct installation position. |

![]()
| Material - Thermal Elastomer | |||
| Width - 7-1/4" | |||
| Length - 5-3/4" | |||
| Height - 3-5/16" | |||
| Color - Gray | |||
| Part Number - 4146910 | |||
| Box Quantity - 10 | |||
Recommended Sealant:
|
Sikaflex® is a registered trademark of Sika Corp (MSDS available via Technical Services webpage)
![]()
| ASTM Method | Test Description | Specification | Test Results |
| D412 | Tensile Strength (min. psi rating) | 1450 psi min. | 1500 psi |
| D412 | Ultimate Elongation (%) | 350 min. | 450 |
| D1171 | Resistance to Ozone-min. rating | 100 (no cracks) | Passed |
| D573 |
Heat Aging - 70 hrs. at 212° F | ||
| Change in Hardness (points) | +/- 15 max. | +3 | |
| Change in Tensile Strength (%) | +/- 30 max. | +2 | |
| Change in elongation (%) | +/- 50 max. | -3 | |
| ASTM Method | Test Description | Specification | Test Results |
| D2137 | Low Temperature Brittleness - 3 mins. at -40° F | Non-brittle | Passed |
| D624 | Tear Resistance Die C (min.) per inch of width min. | 125 pounds per inch of width min. | Passed |
![]()

![]()
| Name | |
| Title | |
| Company | |
| Address | |
| E-mail required | |
| Phone required | use xxx-xxx-xxxx format |
| FAXNumber |
![]()
Last modified: June 24, 2008
Return to Home Page USA only - Information: submit a request or contact us. INTERNATIONAL - Information
ITW Buildex uses WebTrends to analyze traffic to this web site. WebTrends does not create individual profiles for visitors. Unlike some tracking services WebTrends does not have a database of individual profiles for each visitor. WebTrends only collects aggregate data. For more information about WebTrends privacy policy, please click here. Send mail to: webmaster@itwbuildex.com with questions or comments about the webpage. |